Job Archives

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous)
  • Standard Features: 100 Ohm Platinum Stator RTD's (2 per Phase), Space Heaters (120V)
  • Standard Features: Pre-Drilled & Plugged Bearing Bracket for 100 Ohm Platinum Bearing RTD's on 5000 Frames & Above
  • Standard Features: Pre-Drilled & Spot Faced on Top of End Bracket for Vibration Detectors on 5000 Frames and Above
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments Fully Gasketed with NPT Threaded Entrance - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Rotation: F#447-449: Bi-Directional. F#5000-5813: Bi-Directional. 2 Pole Motors F# 5000 or Larger are Uni-Directional, Counter-Clockwise (CCW) facing the Drive End
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction for F#449T and Below
  • Squirrel Cage Copper or Copper Alloy Bar Rotor Construction for F#5000 and Larger
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5B 3.5/0.5
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM
  • Insulated Non-Drive End Bearing on 3600 RPM Motors; 600 HP and Larger
  • Labyrinth Type Metal Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps
  • Grounding Terminal Inside Main Box and on Motor Foot
  • Stainless Steel Nameplate
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • 6 Leads
  • Motors are CSA Approved

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous) Standard Features: 100 Ohm Platinum Stator RTD’s (2 per Phase), Space Heaters (120V) Standard Features: Pre-Drilled & Plugged Be...

      Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • Class I, Div. 1, Group C & D and Class II, Groups E, F and G - Temp Code T2D/T3B Up to and Including F# 256T
  • Class I, Div. 1, Group D and Class II, Groups E, F and G - Temp Code T2D/T3B for F# 284T and Larger
  • UL File: E84757
  • CSA File: #64671
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Dual Drilled Back Feet on 447/9 and 5007/9 Frames
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • Cast Iron Frame, Fan Cover, End Brackets and Main Conduit Box
  • Capable of Withstanding Explosion Force as Required by UL
  • Stainless Steel Breather Drains with Bronze Filters (For Horizontal Mount Only)
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction through 449 Frame; Fabricated Copper Bar on 5000 Frame
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Blue - Munsell 5 PB 4.5/2
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM for F# 280TS and Larger
  • Bronze Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
  • Stainless Steel Nameplate
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • UL Listed for Inverter Duty
  • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of up to 2200 Volts
  • Inverter Duty Speed Ranges:
    • VT = 3 - 60 Hz
    • CT for 140T - 210T Frames = 10 - 60 Hz
    • CT for 250T - 320T Frames = 13 - 60 Hz
    • CT for 260T - 440T Frames = 16 - 60 Hz
  • 9 Leads for 5 HP and Smaller;
  • 12 Leads for 7.5 HP to 125 HP;
  • 6 Leads for 150 HP and Larger

      Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) Class I, Div. 1, Group C & D and Class II, Groups E, F and G – Temp Code T2D/...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • Class I, Div. 1, Group C & D and Class II, Groups E, F and G - Temp Code T2D/T3B Up to and Including F# 256T
  • Class I, Div. 1, Group D and Class II, Groups E, F and G - Temp Code T2D/T3B for F# 284T and Larger
  • UL File: E84757
  • CSA File: #64671
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Dual Drilled Back Feet on 447/9 and 5007/9 Frames
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • Cast Iron Frame, Fan Cover, End Brackets and Main Conduit Box
  • Capable of Withstanding Explosion Force as Required by UL
  • Stainless Steel Breather Drains with Bronze Filters (For Horizontal Mount Only)
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction through 449 Frame; Fabricated Copper Bar on 5000 Frame
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Blue - Munsell 5 PB 4.5/2
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM for F# 280TS and Larger
  • Bronze Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
  • Stainless Steel Nameplate
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • UL Listed for Inverter Duty
  • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of up to 2200 Volts
  • Inverter Duty Speed Ranges:
    • VT = 3 - 60 Hz
    • CT for 140T - 210T Frames = 10 - 60 Hz
    • CT for 250T - 320T Frames = 13 - 60 Hz
    • CT for 260T - 440T Frames = 16 - 60 Hz
  • 9 Leads for 5 HP and Smaller;
  • 12 Leads for 7.5 HP to 125 HP;
  • 6 Leads for 150 HP and Larger

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) Class I, Div. 1, Group C & D and Class II, Groups E, F and G – Temp Code T2D/T3B Up to a...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Stainless Steel Frame, End Brackets and Hardware
  • Grounding Terminal Inside Main Conduit Box
  • Stainless Steel Oversized Main Conduit Box - F3 Mounted (IM1001)
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • SUS304 Stainless Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL
  • Contact Lip Type Seal on Both Ends
  • Etched Nameplate on the Stainless Steel Frame
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 10:1 Variable Torque, 4:1 Constant Torque
  • 9 Leads
  • Two Drain Holes on Bottom of Frame and one in the C-Flange
  • Motors are U.L. Recognized, CSA Approved and CE Marked
  • Department of Energy Efficiency Certificate # CC082A
  • Encapsulated Windings as Option

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) Class F Insulation Class B Temperature Rise NEMA Design B Torques Stainless Steel Frame, End Brack...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • Grounding Ring Factory Installed Externally on NDE Bracket
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Rolled Steel Frame, Fan Cover, and Main Conduit Box
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted Only (F2 not available)
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • Cast Iron End Brackets
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Blue - Munsell 5PB 3/8
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL (Non-regreasable)
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque
  • 9 Leads for 5 HP and Smaller;
  • 12 Leads for 7.5 HP and Larger
  • Motors are U.L. Recognized for United States and Canada, CSA Approved and CE Marked

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) Grounding Ring Factory Installed Externally on NDE Bracket Class F Insulation Class B Temperature ...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design D Torques
  • Cast Iron Frame, End Brackets, Fan Cover and Main Conduit Box
  • Grounding Terminal Inside Main Conduit Box with additional Foot Grounding Provision
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F2 Mounted, F1 Available with Modification
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint System: Phenolic Rust Proof Base with Alkyd Finish
  • Paint Color: Dark Blue (Munsell 5PB 4.5/2)
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 280T and Smaller (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM for F# 320T and Larger
  • Labyrinth Type Metal Flinger on Both Ends for Frames F# 320T and Larger
  • Cast Iron Inner and Outer Bearing Caps for F# 324T and Larger
  • Stainless Steel Nameplate
  • 12 Leads
  • Standard with Klixon 9700K Temperature Limiting Switch, 1 Per Phase
  • 5% Minimum Slip

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous) Class F Insulation Class B Temperature Rise NEMA Design D Torques Cast Iron Frame, End Brackets, Fan Cover and Main Conduit Box Grounding ...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • Factory Self-Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3C Minimum
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C
  • Cast Iron Frame, End Brackets, Main Conduit Box; Rolled Steel Fan Cover
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5B 3.5/0.5
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM for F# 280TS and Larger
  • Automatic Grease Discharge Fittings on Regreasable Models
  • Labyrinth Type Metal Flinger on Both Ends for F# 280TS and Larger
  • Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
  • Stainless Steel Nameplate
  • Suitable for Inverter Duty per NEMA MG-1, Part 30
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque
  • 9 Leads for 5 HP and Smaller;
  • 12 Leads for 7.5 HP to 125 HP;
  • Motors are U.L. Recognized, CSA Approved and CE Marked
  • Rubber Dust Flinger on Drive-End for F# 140T - 280T

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) Factory Self-Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3C Minimum Class F I...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3C Minimum
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C
  • Cast Iron Frame and End Brackets; Rolled Steel Fan Cover and Main Conduit Box
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5B 3.5/0.5
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM for F# 280TS and Larger
  • Automatic Grease Discharge Fittings on Regreasable Models
  • Labyrinth Type Metal Flinger on Both Ends for F# 280TS and Larger
  • Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque
  • 9 Leads for 5 HP and Smaller;
  • 12 Leads for 7.5 HP to 125 HP;
  • 6 Leads for 150 HP and Larger
  • Motors are U.L. Recognized, CSA Approved and CE Marked
  • Dual Drilled Feet Available on Most Ratings - Longer Frames (i.e. 145T Drilled also for 143T)
  • Provisions for Breather Drains for Vertical Mount Down (F# 324T and Larger)
  • Rubber Dust Flinger on Drive-End for F# 140T - 280T

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3C Minimum Class F Insulation...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • Class F Insulation
  • Class B Temperature Rise
  • Cast Iron Frame, End Brackets and Main Conduit Box; Rolled Steel Fan Cover
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F3 Mounted (IM1001)
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Blue - Munsell 5PB 3/8
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 80 - 225 (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with with MULTEMP SRL for F# 250 and Larger
  • Oil Seal/V-Ring on Both Ends
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque
  • 6 Leads
  • Motors are CE Marked

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) Class F Insulation Class B Temperature Rise Cast Iron Frame, End Brackets and Main Conduit Box; Ro...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (Frame 444T and above)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design A Torques; Equal or Greater Than 200% Starting Torque / 250% Breakdown Torque
  • Cast Iron Frame, End Brackets, Main Conduit Box; Rolled Steel Fan Cover
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • High Strength 4140 AISI Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5 BG 3.5/0.5
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM
  • Automatic Grease Discharge Fittings
  • Gamma (Axial Face) Seal on Both Ends for F# 140T - 400T
  • Labyrinth Type Metal Flinger on Both Ends for F# 440T and Larger
  • Cast Iron Inner and Outer Bearing Caps for F# 320T and Larger
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
  • 12 Leads for 125 HP and Smaller
  • 6 Leads for 150 HP and Larger
  • Standard With Thermistors (PTC 140˚C) 1 per Phase
  • Locknut and Washer on NDE for Vertical Shaft Down Applications on F# 440 and Larger
  • Drain Holes / Plugs on Both End Brackets for Vertical Applications
  • Threaded One Way Breather Drains for Horizontal Mount Applications

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3 Minimum CSA Certified for C...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (Frame 444T and above)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design A Torques; Equal or Greater Than 200% Starting Torque / 250% Breakdown Torque
  • Cast Iron Frame, End Brackets, Main Conduit Box; Rolled Steel Fan Cover
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • High Strength 4140 AISI Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5 BG 3.5/0.5
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil PolyrexTM EM
  • Automatic Grease Discharge Fittings
  • Gamma (Axial Face) Seal on Both Ends for F# 140T - 400T
  • Labyrinth Type Metal Flinger on Both Ends for F# 440T and Larger
  • Cast Iron Inner and Outer Bearing Caps for F# 320T and Larger
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
  • 12 Leads for 125 HP and Smaller
  • 6 Leads for 150 HP and Larger
  • Standard With Thermistors (PTC 140˚C) 1 per Phase
  • Locknut and Washer on NDE for Vertical Shaft Down Applications on F# 440 and Larger
  • Drain Holes / Plugs on Both End Brackets for Vertical Applications
  • Threaded One Way Breather Drains for Horizontal Mount Applications

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3 Minimum CSA Certified for C...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (Frame 444T and above)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design A Torques; Equal or Greater Than 200% Starting Torque / 250% Breakdown Torque
  • Cast Iron Frame, End Brackets; Pressed Steel Plate Main Conduit Box and Fan Cover
  • Cast Iron Main Conduit Box on 505UZ Frame
  • Grounding Terminal Inside Main Conduit Box with additional Foot Grounding Provision
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • High Strength 4140 AISI Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Dark Gray - Munsell 7.5 BG 3.5/0.5
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM
  • Automatic Grease Discharge Fittings
  • Labyrinth Type Metal Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
  • 6 Leads
  • Standard With Thermistors (PTC 140˚C) 1 per Phase
  • Locknut and Washer on NDE for Vertical Shaft Down Applications
  • Drain Holes / Plugs on Both End Brackets for Vertical Applications
  • Threaded One Way Breather Drains for Horizontal Mount Applications

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3 Minimum CSA Certified for C...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (Frame 444T and Above)
  • Meets or Exceeds IEEE 841 Standards
  • Meets IEEE 45 Marine Duty and ABS Design Assessment up to 500 HP(2,4,6 pole only)
  • Extended Warranty - 60 Months from Date of Manufacture
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C
  • Cast Iron Frame, End Brackets & Fan Cover and Main Conduit Box
  • Grounding Terminal Inside Main Conduit Box with additional Foot Grounding Provision
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 50˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation; Except 2 Pole "Hybrid" and F# 5000 and Larger Ratings are Counter-Clockwise facing the DE
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction for F# 140T - 449T Copper/Copper Alloy Rotor Construction for F# 5000 and Larger
  • Paint System: 2 Part Epoxy
  • Paint Color: Blue - Munsell 5PB 3/8
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM
  • Automatic Grease Discharge Fittings
  • VBXX INPRO™ Seals Installed on Both Ends
  • Stainless Steel Nameplate and Hardware
  • Stainless Steel Automatic Breather Drain
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
  • Motors are U.L. Recognized, CSA Approved
  • 3 Leads Only
  • Dual Drilled Feet Available on Most Ratings - Longer Frames (i.e. 145T Drilled also for 143T)
  • Vibration Not to Exceed 0.08 Inches Per Second
  • Noise Level Not to Exceed 85 dB(A) at 1 Meter Unloaded

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3 Minimum CSA Certified for C...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Minimum
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Minimum (444T and above)
  • IEEE 841 Ready
  • Meets IEEE 45 Marine Duty
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C
  • Cast Iron Frame, End Brackets & Fan Cover and Main Conduit Box
  • Grounding Terminal Inside Main Conduit Box with additional Foot Grounding Provision
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction
  • Paint System: 2 Part Epoxy
  • Paint Color: Blue - Munsell 5PB 3/8
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM
  • Automatic Grease Discharge Fittings
  • Rubber Dust Flinger on DE for F# 140T - 280T
  • Oil Seal/V-Ring on Both Ends for F# 320T - 400T
  • Labyrinth Type Metal Flinger on Both Ends for F# 440T and Larger
  • Cast Iron Inner and Outer Bearing Caps for F# 400T and Larger
  • Stainless Steel Nameplate and Hardware
  • Stainless Steel Automatic Breather Drain
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Use per NEMA MG-1.4.4.2, Part 31
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
  • Motors are U.L. Recognized, CSA Approved
  • 3 Leads Only
  • Dual Drilled Feet Available on Most Ratings - Longer Frames (i.e. 145T Drilled also for 143T)
  • Vibration Not to Exceed 0.08 Inches Per Second
  • Noise Level Not to Exceed 85 dB(A) at 1 Meter Unloaded

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3 Minimum CSA Certified for C...

Features

  • Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous)
  • CSA Certified for Class I, Div. 2, Groups B, C, D - Temp Code T3 Maximum
  • CSA Certified for Class II, Div. 2, Groups F & G - Temp Code T3 Maximum (Frame 444T and Above)
  • Class F Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques as a Minimum; Various Ratings also Meet Design C
  • Cast Iron Frame, End Brackets & Fan Cover and Main Conduit Box
  • Grounding Terminal Inside Main Conduit Box
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments - F1 Mounted
  • Designed for 40˚C Ambient Temperature
  • Designed for 3300 ft. Elevation
  • Bi-Directional Rotation; Except 2 Pole "Hybrid" and F# 5000 and Larger Ratings are Counter-Clockwise facing the DE
  • 1045 Carbon Steel Shaft
  • Aluminum Die Cast Squirrel Cage Rotor Construction for F# 140T - 449T Copper/Copper Alloy Rotor Construction for F# 5000 and Larger
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Light Gray - Munsell N5.0
  • Double Shielded Bearings Pre-Packed with MULTEMP SRL for F# 140T - 280T (Non-regreasable)
  • High Quality Ball (or Roller) Bearings Regreasable with Mobil Polyrex™ EM Grease for F# 280TS and Larger
  • Automatic Grease Discharge Fittings on Regreasable Models
  • Labyrinth Type Metal Flinger on Both Ends for F# 280TS and Larger
  • Cast Iron Inner and Outer Bearing Caps for F#280TS and Larger
  • Stainless Steel Nameplate
  • New Dual Column Design Nameplate as Standard (60/50 Hz)
  • Suitable for Inverter Duty (PWM - Pulse Width Modulation) per NEMA MG-1, Part 30
  • Inverter Duty Speed Range: 20:1 Variable Torque, 10:1 Constant Torque (350 HP and Larger are 3:1 Constant Torque)
  • 9 Leads for 5 HP and Smaller;
  • 12 Leads for 7.5 HP to 125 HP;
  • 6 Leads for 150 HP and Larger
  • Motors are U.L. Recognized, CSA Approved and CE Marked
  • Dual Drilled Feet Available on Most Ratings - Longer Frames (i.e. 145T Drilled also for 143T)
  • Insulated Non-Drive End Bearing on 2-Pole Motors 600 HP and Larger
  • Rubber Dust Flinger on Drive-End for F# 140T - 280T

Features Three Phase, 60 Hz, 1.15 Service Factor (Continuous); 50 Hz, 1.0 Service Factor (Continuous) CSA Certified for Class I, Div. 2, Groups B, C, D – Temp Code T3 Maximum CSA Certified for C...